Fs-Elliott艾律德700HP離心式空壓機AT-CDA-B2-05
設備巡檢紀錄 - FS-Elliott艾律德700HP離心式空壓機檢查表(AT)
|
檢查項目
|
參考值
|
單位
|
1
|
2
|
3
|
4
|
5
|
6
|
7
|
8
|
9
|
10
|
11
|
12
|
13
|
14
|
15
|
16
|
17
|
18
|
19
|
20
|
21
|
22
|
23
|
24
|
25
|
26
|
27
|
28
|
29
|
30
|
31
|
|
壓縮機通電時間 |
|
|
114335 |
114361 |
114385 |
114410 |
95160 |
95184 |
114481 |
114505 |
114529 |
114553 |
95306 |
95329 |
95352 |
114649 |
114673 |
114697 |
95449 |
95473 |
114770 |
114793 |
|
|
|
|
|
|
|
|
|
|
|
|
壓縮機運行時間 |
|
|
95061 |
95087 |
95111 |
95135 |
114434 |
114458 |
95207 |
95231 |
95255 |
95279 |
114580 |
114603 |
114626 |
95375 |
95399 |
95423 |
114723 |
114747 |
95496 |
95519 |
|
|
|
|
|
|
|
|
|
|
|
|
進氣閥 |
|
% |
50 |
52 |
60 |
51 |
54 |
58 |
53 |
59 |
58 |
56 |
66 |
65 |
58 |
52 |
50 |
52 |
58 |
57 |
56 |
59 |
|
|
|
|
|
|
|
|
|
|
|
|
卸載閥 |
|
% |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
|
|
|
|
|
|
|
|
|
|
|
|
排氣壓力 |
|
kg |
7.8 |
7.8 |
7.8 |
7.8 |
7.9 |
7.9 |
7.8 |
7.8 |
7.5 |
7.9 |
7.9 |
7.8 |
7.8 |
7.8 |
7.9 |
7.8 |
7.6 |
7.9 |
7.9 |
7.8 |
|
|
|
|
|
|
|
|
|
|
|
|
油溫 |
≦57 |
℃ |
43.8 |
43.8 |
43.8 |
43.8 |
43.8 |
43.8 |
43.7 |
43.9 |
43.8 |
43.8 |
43.6 |
43.9 |
43.9 |
43.8 |
43.8 |
43.9 |
43.9 |
43.8 |
43.8 |
43.8 |
|
|
|
|
|
|
|
|
|
|
|
|
油壓 |
≧1.4 |
kg |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
2.3 |
|
|
|
|
|
|
|
|
|
|
|
|
低速振動 |
≦18 |
um |
2.90 |
2.87 |
2.81 |
2.94 |
2.85 |
2.8 |
2.85 |
2.77 |
2.83 |
2.63 |
2.82 |
2.86 |
2.75 |
2.87 |
2.85 |
2.84 |
2.8 |
2.8 |
2.84 |
2.86 |
|
|
|
|
|
|
|
|
|
|
|
|
高速振動 |
≦18 |
um |
7.73 |
7.44 |
7.37 |
7.3 |
7.26 |
7.21 |
7.34 |
7.21 |
7.32 |
7.32 |
7.3 |
7.2 |
7.21 |
7.17 |
7.37 |
7.51 |
7.3 |
7.5 |
7.51 |
7.35 |
|
|
|
|
|
|
|
|
|
|
|
|
馬逹電流 |
≦780 |
A |
759 |
757 |
760 |
764 |
760 |
761 |
761 |
757 |
760 |
761 |
758 |
761 |
760 |
760 |
761 |
759 |
761 |
760 |
760 |
762 |
|
|
|
|
|
|
|
|
|
|
|
|
末級温度 |
≦30 |
℃ |
30.6
|
30.1
|
30.9
|
30 |
30.2
|
29.9 |
29.6 |
31.2
|
30.7
|
30.7
|
31.3
|
32.2
|
32.2
|
30.7
|
30.7
|
31.5
|
31.6
|
30.9
|
30.8
|
30.3
|
|
|
|
|
|
|
|
|
|
|
|
|
系統壓力 |
|
kg |
7.1 |
7.1 |
7.1 |
7.1 |
7.1 |
7.1 |
7.1 |
7.0 |
7.1 |
7.1 |
7.2 |
7 |
7 |
7.0 |
7.1 |
7.0 |
6.8 |
7.1 |
7.1 |
7.1 |
|
|
|
|
|
|
|
|
|
|
|
|
IAT 一級溫度 |
≦40 |
℃ |
31 |
30 |
31 |
30 |
30 |
30 |
30 |
31 |
31 |
31 |
31 |
32 |
32 |
31 |
31 |
31 |
32 |
31 |
31 |
30 |
|
|
|
|
|
|
|
|
|
|
|
|
IAT 二級溫度 |
≦40 |
℃ |
43
|
43
|
44
|
43
|
44
|
44
|
44
|
46
|
44
|
45
|
44
|
44
|
44
|
45
|
45
|
46
|
44
|
44
|
45
|
45
|
|
|
|
|
|
|
|
|
|
|
|
|
ACT出口溫度 |
≦30 |
℃ |
39
|
39
|
39
|
38
|
39
|
38
|
38
|
40
|
39
|
39
|
40
|
40
|
40
|
39
|
39
|
40
|
40
|
39
|
40
|
39
|
|
|
|
|
|
|
|
|
|
|
|
|
IMT馬逹前軸承溫度 |
≦90 |
℃ |
65 |
65 |
65 |
65 |
65 |
64 |
64 |
64 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
65 |
|
|
|
|
|
|
|
|
|
|
|
|
OMT馬逹後軸承溫度 |
≦90 |
℃ |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
58 |
|
|
|
|
|
|
|
|
|
|
|
|
SMT馬逹定子溫度 |
≦145 |
℃ |
81 |
81 |
81 |
81 |
81 |
81 |
81 |
81 |
81 |
81 |
82 |
82 |
81 |
81 |
81 |
81 |
82 |
81 |
81 |
81 |
|
|
|
|
|
|
|
|
|
|
|
|
FDT一級排氣壓力 |
|
kg |
1.6 |
1.6 |
1.6 |
1.6 |
1.9 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.7 |
1.7 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
|
|
|
|
|
|
|
|
|
|
|
|
SDT一級排氣壓力 |
|
kg |
4.3 |
4.3 |
4.4 |
4.3 |
4.3 |
4.4 |
4.3 |
4.3 |
4.3 |
4.3 |
4.4 |
4.4 |
4.4 |
4.3 |
4.3 |
4.3 |
4.3 |
4.4 |
4.4 |
4.4 |
|
|
|
|
|
|
|
|
|
|
|
|
油冷却器進水溫度 |
|
℃ |
12 |
12 |
12 |
10 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
油冷却器出水溫度 |
|
℃ |
14 |
14 |
14 |
14 |
12 |
15 |
14 |
14 |
14 |
14 |
15 |
15 |
15 |
14 |
14 |
14 |
14 |
13 |
14 |
13 |
|
|
|
|
|
|
|
|
|
|
|
|
第一段冷却器進水溫度 |
|
℃ |
12 |
12 |
12 |
12 |
12 |
12 |
11 |
12 |
12 |
12 |
12 |
12 |
15 |
12 |
12 |
12 |
13 |
12 |
12 |
12 |
|
|
|
|
|
|
|
|
|
|
|
|
第一段冷却器出水溫度 |
|
℃ |
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
NA
|
|
|
|
|
|
|
|
|
|
|
|
|
第二段冷却器進水溫度 |
|
℃ |
14 |
14 |
15 |
15 |
15 |
15 |
15 |
15 |
14 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
15 |
|
|
|
|
|
|
|
|
|
|
|
|
第二段冷却器出水溫度 |
|
℃ |
38 |
37 |
38 |
36 |
35 |
37 |
37 |
40 |
38 |
38 |
40 |
40 |
40 |
38 |
38 |
40 |
39 |
38 |
38 |
38 |
|
|
|
|
|
|
|
|
|
|
|
|
第三段冷却器進水溫度 |
|
℃ |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
20 |
22 |
20 |
22 |
20 |
20 |
20 |
20 |
22 |
20 |
20 |
|
|
|
|
|
|
|
|
|
|
|
|
第三段冷却器出水溫度 |
|
℃ |
24 |
24 |
23 |
22 |
25 |
22 |
22 |
24 |
24 |
24 |
25 |
25 |
25 |
24 |
24 |
24 |
25 |
25 |
24 |
24 |
|
|
|
|
|
|
|
|
|
|
|
| 備註 |
1.(V):正常/(X):異常;有操作參數則需填入檢查數據。
2.若該設備無此項檢查項目時,請填寫NA。
3.此表單由廠房設施部存查,保存期限三年。
|
| 紀錄者 |
楊植鈞
|
楊植鈞
|
楊植鈞
|
張家韋
|
黃立凱
|
黃立凱
|
楊植鈞
|
楊植鈞
|
楊植鈞
|
楊植鈞
|
黃立凱
|
黃立凱
|
黃立凱
|
楊植鈞
|
楊植鈞
|
楊植鈞
|
黃立凱
|
黃立凱
|
楊植鈞
|
楊植鈞
|
|
|
|
|
|
|
|
|
|
|
|